S-100R is compatible with S-100 and shows better performance including 5% input voltage tolerance besides its persistent stability and Temperature Effect Resistance for various application from Wall Pad, cars, houses, schools and offices to harsh application of stocks raising, greenhouse, scientific projects, etc. S-100R/A is operate as ACDL (Automatic Calibration) without hardware setting, it is favorable by them whose application is Indoor Airquality Monitoring.
|
|
|
|
|
|
|
Features |
NDIR Type
Available outputs : AVO, TTL UART, I2C
Re-calibrationfunction (Weekly period/10 min. period)-Optional
Size - 33mm×33mm×13.1mm |
General Performance |
Operating Humidity range => 0 ~ 95% RH (Non-condensing)
Operating Temperature => -5 ~ 55¡É
StorageTemperature => -30¡É ~ 70 ¡É |
Measurement |
Sensing method => NDIR (Non-dispersive Infrared)
Measurement range => 0 to 2,000/3,000/5,000/10,000 ppm, 2%, 3% (Optional)
Accuracy => ±50ppm ±3% measured value
Response Time (90%) => 60 sec
Sampling Interval => 3 sec |
Electrical |
InputPower=>4.75 ~ 5.25V (5.0V ±5% Regulation)
Power consumption => Normal : 20mA, Max : 380mA at lamp on peak
Output connector => 4pin/10pin (2mm Pitch Socket) |
Output |
Digital=> UART- 38,400BPS, 8bit, No parity, 1 stop bit TTL Level
Analog => VDC 0.5 ~ 4.5V (linear output)
I2C => Slave |
|
|
|
|
|
|